Creating a trigger that transmits messages to a Cloud Functions function from an Yandex IoT Core registry or device topic
Create a trigger for a Yandex IoT Core device or registry topic and process message copies using the Yandex Cloud Functions function.
Warning
The trigger must be in the same cloud as the registry or device whose topic it reads messages from.
Getting started
To create a trigger, you need:
-
A function that the trigger will invoke. If you do not have a function:
-
(Optional) A dead-letter queue where messages that could not be processed by a function will be redirected. If you do not have a queue, create one.
-
Service accounts with permissions to invoke the function and (optionally) write messages to the dead-letter queue. You can use the same service account or different ones. If you do not have a service account, create one.
- Registry or device from whose topics the trigger will receive message copies. If you have neither:
Creating a trigger
Note
The trigger is initiated within 5 minutes of being created.
-
In the management console
, select the folder where you want to create a trigger. -
Select Cloud Functions.
-
In the left-hand panel, select
Triggers. -
Click Create trigger.
-
Under Basic settings:
- Enter a name and description for the trigger.
- In the Type field, select
IoT Core (device)
. - In the Launched resource field, select
Function
.
-
Under IoT Core message settings, specify the registry, device, and MQTT topic to create a trigger for. When creating a trigger for a registry topic, you do not need to specify a device or an MQTT topic. If no MQTT topic is set, the trigger fires for all registry or device topics.
-
Under Batch message settings, specify:
- Waiting time, s. The values may range from 1 to 60 seconds. The default value is 1 second.
- Batch size. The values may range from 1 to 100. The default value is 1.
The trigger groups messages for a period of time not exceeding the specified timeout and sends them to a function. The number of messages cannot exceed the specified batch size.
-
Under Function settings, select a function and specify:
- Function version tag.
- Service account to invoke the function under.
-
(Optional) Under Repeat request settings:
- In the Interval field, specify the time after which the function will be invoked again if the current attempt fails. The values may range from 10 to 60 seconds. The default value is 10 seconds.
- In the Number of attempts field, specify the number of invocation retries before the trigger moves a message to the Dead Letter Queue. The values may range from 1 to 5. The default value is 1.
-
(Optional) Under Dead Letter Queue settings, select the dead letter queue and the service account with write permissions for this queue.
-
Click Create trigger.
If you do not have the Yandex Cloud command line interface yet, install and initialize it.
The folder specified in the CLI profile is used by default. You can specify a different folder using the --folder-name
or --folder-id
parameter.
To create a trigger that invokes a function, run this command:
yc serverless trigger create internet-of-things \
--name <trigger_name> \
--registry-id <registry_ID> \
--device-id <device_ID> \
--mqtt-topic '<MQTT_topic>' \
--batch-size <message_batch_size> \
--batch-cutoff <maximum_wait_time> \
--invoke-function-id <function_ID> \
--invoke-function-service-account-id <service_account_ID> \
--retry-attempts <number_of_retry_invocation_attempts> \
--retry-interval <interval_between_retry_attempts> \
--dlq-queue-id <dead_letter_queue_ID> \
--dlq-service-account-id <service_account_ID>
Where:
--name
: Trigger name.--registry-id
: Registry ID.--device-id
: Device ID. If you are creating a trigger for a registry topic, you can omit this parameter.--mqtt-topic
: MQTT topic you want to create a trigger for. This is an optional parameter. If this parameter is skipped, the trigger fires for all registry or device topics.
--batch-size
: Size of the message batch from MQTT topics. This is an optional parameter. The values may range from 1 to 10. The default value is 1.--batch-cutoff
: Maximum waiting time. This is an optional parameter. The values may range from 1 to 60 seconds. The default value is 1 second. The trigger groups messages for a period not exceedingbatch-cutoff
and sends them to a function. The number of messages cannot exceedbatch-size
.
--invoke-function-id
: Function ID.--invoke-function-service-account-id
: ID of the service account with permissions to invoke the function.--retry-attempts
: Number of invocation retries before the trigger moves a message to the dead-letter queue. This is an optional parameter. The values may range from 1 to 5. The default value is 1.--retry-interval
: Time after which the function will be invoked again if the current attempt fails. This is an optional parameter. The values may range from 10 to 60 seconds. The default value is 10 seconds.--dlq-queue-id
: Dead-letter queue ID. This is an optional parameter.--dlq-service-account-id
: ID of the service account with write permissions to the dead-letter queue. This is an optional parameter.
Result:
id: a1sl0mkmimfj********
folder_id: b1g88tflru0e********
created_at: "2019-09-25T13:54:35.654935Z"
name: iot-trigger
rule:
iot_message:
registry_id: arenou2oj4ct********
device_id: areqjd6un3af********
mqtt_topic: $devices/areqjd6un3af********/events
batch_settings:
size: "1"
cutoff: 0s
invoke_function:
function_id: d4eofc7n0m03********
function_tag: $latest
service_account_id: aje3932acd0c********
retry_settings:
retry_attempts: "1"
interval: 10s
status: ACTIVE
Terraform
For more information about the provider resources, see the documentation on the Terraform
If you change the configuration files, Terraform automatically detects which part of your configuration is already deployed, and what should be added or removed.
If you don't have Terraform, install it and configure the Yandex Cloud provider.
To create a trigger for Yandex IoT Core:
-
In the Terraform configuration file, describe the parameters of the resources you want to create:
resource "yandex_function_trigger" "my_trigger" { name = "<trigger_name>" description = "<trigger_description>" function { id = "<function_ID>" service_account_id = "<service_account_ID>" retry_attempts = "<number_of_retry_invocation_attempts>" retry_interval = "<interval_between_retry_attempts>" } iot { registry_id = "<registry_ID>" device_id = "<device_ID>" topic = "<MQTT_topic>" batch_cutoff = "<maximum_timeout>" batch_size = "<message_batch_size>" } dlq { queue_id = "<dead_letter_queue_ID>" service_account_id = "<service_account_ID>" } }
Where:
-
name
: Trigger name. The name format is as follows:- The name must be from 3 to 63 characters long.
- It may contain lowercase Latin letters, numbers, and hyphens.
- The first character must be a letter and the last character cannot be a hyphen.
-
description
: Trigger description. -
function
: Function parameters:id
: Function ID.service_account_id
: ID of the service account with permissions to invoke the function.retry_attempts
: Number of invocation retries before the trigger moves a message to the dead-letter queue. This is an optional parameter. The values may range from 1 to 5. The default value is 1.retry_interval
: Time until another attempt is made to invoke the function if the current attempt fails. This is an optional parameter. The values may range from 10 to 60 seconds. The default value is 10 seconds.
-
iot
: Trigger parameters:registry-id
: Registry ID.device-id
: Device ID. If you are creating a trigger for a registry topic, you can omit this parameter.topic
: MQTT topic you want to create a trigger for. This is an optional parameter. If this parameter is skipped, the trigger fires for all registry or device topics.batch_cutoff
: Maximum wait time. This is an optional parameter. The values may range from 1 to 60 seconds. The default value is 1 second. The trigger groups messages for a period not exceedingbatch-cutoff
and sends them to a function. The number of messages cannot exceedbatch-size
.batch-size
: Size of the message batch from MQTT topics. This is an optional parameter. The values may range from 1 to 10. The default value is 1.
dlq
: Dead-letter queue message parameters:queue_id
: Dead-letter queue ID. This is an optional parameter.service_account_id
: ID of the service account with write permissions to the dead-letter queue. This is an optional parameter.
For more information about the
yandex_function_trigger
resource parameters, see the provider documentation . -
-
Create resources:
-
In the terminal, change to the folder where you edited the configuration file.
-
Make sure the configuration file is correct using the command:
terraform validate
If the configuration is correct, the following message is returned:
Success! The configuration is valid.
-
Run the command:
terraform plan
The terminal will display a list of resources with parameters. No changes are made at this step. If the configuration contains errors, Terraform will point them out.
-
Apply the configuration changes:
terraform apply
-
Confirm the changes: type
yes
in the terminal and press Enter.
Terraform will create all the required resources. You can check the new resources using the management console
or this CLI command:yc serverless trigger list
-
To create a trigger for Yandex IoT Core, use the create REST API method for the Trigger resource or the TriggerService/Create gRPC API call.
Checking the result
Check that the trigger operates correctly. Do it by viewing function logs that present information on invocations.